Digi-Cool Digital Refrigeration System Analyzer
Our Item Number: HV608-1100
Manufacturer: Digi Cool
Manufacturer Number: DRSA1200
Product Type: Refrigerant Analyzer
BUY
NOW |
|
Get all your diagnostic questions answered with the Digi-Cool Digital Refrigeration System Analyzer!
Features & Applications:
A great deal of information lies hidden behind the vibrating needle of a typical pressure gauge. Is the TEV valve modulating properly, or is there liquid flooding back in the system?
Digi-Cool offers unprecedented diagnostic power with the Digital Refrigeration System Analyzer (DRSA). The patented pressure bar graphs allow you to see pressure dynamics intuitively for quick diagnosis. Automatic saturation, subcooling and superheat readings mean no more wallet cards. Conceived by a technician with modern engineering, the unit will endure years of field use.
The new DRSA-1100 features an integrated temperature probe to automatically calculate superheat and subcooling, and pressure extremes monitoring for simple pressure controls set-up, for even greater convenience during start-ups.
Features:
- Includes profiles for 23 common refrigerants within:
R-12 R-22 R-134A R-290
R-401A R-401B R-402A R-402B
R-404A R-406A R-407C R-408A
R-409A R-410A R-414B R-416A
R-417A R-420A R-422A R-502
R-507 R-508B R-600A
- "Dynamic Offset" bar graph clearly shows modulation of
control valves, system behavior and faults
- New: Temperature probe for automatic superheat and
subcooling readings
- New: Max and min pressure monitoring for control set-up
- Auto zero key eliminates manual recalibration
- Detects vacuums in “Hg
- Easy to read LCD screen with large digits
- Upgradeable for additional refrigerants
- Splash resistant and wide temperature range for indoor &
outdoor use; case resistant to typical oils, acids and sun
exposure
- Advanced, durable tool for the
professional HVAC&R technician
- Service Manifold not included
- New: Sleeker shape
- Protective rubber boot
Spec Summary:
Accuracy: |
0.5% F.S. ± 1 least significant digit, calibration traceable to NIST |
Pressure Ports: |
1/8" NPT supplied with swivel joints and street elbows to fit your manifold |
Working Pressure: |
Low side: 0-200psia (1350 kPa) High side: 0-550psia (3000 kPa) |
Proof Pressure: |
Low side: 600psia (4100 kPa) High side: 1500psia (10300 kPa) |
Burst Pressure: |
Low side: 2000psia (13500 kPa) High side: 5000psia (34500 kPa) |
Temperature Sense: |
-40 to 250°F (-40 to 125°C), ±0.9°F (±0.5°C) between 32 to 158°F (0 to 70°C) |
Usage Environment: |
Indoor/Outdoor AMBIENT TEMPERATURE: -4 to 122°F (-20 to 50°C) |
Moisture Exposure: |
Dew, splash and rain resistant; do not immerse in water |
Power Supply: |
9V battery |
Weight: |
1.6lb (740g) |
Battery Life: |
approx. 6 months under normal use |
Dimensions: |
7.3 x 4.9 x 2.7" (18.5 x 12.5 x 6.8cm) |
|
|